HG Series Touch Screen Gloss Meter HG268
HG series economic gloss meter is independently developed by 3nh, with independent intellectual property. Manufactured according to International standard ISO2813and Chinesestandard GB/T 9754,it is the world's first full large touch screen gloss meter.
Key Highlights
Large Touch Screen Operation, Fully Automatic Calibration
Tri-Angle 20°, 60°, 85° Test
Display 5 sets of measurement data
Ergonomic Design
One button for all angles measurement at the same location
Data Storage & Connectivity
Achieve precise gloss control with 3nh's cutting-edge portable gloss tester. Engineered for industrial applications, this compact instrument delivers instant, accurate readings for coatings, plastics, metals, and more.
Key features include:
Tri-Angle Technology (20°, 60°, 85°) for comprehensive surface analysis
High Precision compliant with ISO, ASTM, and DIN standards
Ultra-Fast Measurement (<1 second) for efficient quality control
Data Storage & Connectivity for seamless integration into workflows
Ergonomic Design for one-handed operation in field or lab settings
Trusted by industries worldwide, 3nh's gloss meters ensure consistency, reduce waste, and enhance product aesthetics. Ideal for automotive, aerospace, printing, and manufacturing.
HG268 gloss meter features with 20, 60 and 85° angle, manufactured according to ISO2813 and GB/T 9754. It is also compatible with international standards of ASTM D523, ASTM D2457. HG268 conforms to JJG696 first class gloss meter working requirement, corresponding with CIE 1931(2°) under CIE C light source.
HG268 gloss meter is widely used to test glossiness in these industries, such as automobile, paint, ink, stoving varnish, coating, wood products, marble, granite, vitrified polished tile, pottery brick and porcelain, plastic, paper; hardware industries, etc.
GQC6 Software Introduction:
GQC6 software is used with 3nh gloss meter for PC connection, measurement, data management, data export, print reports, etc.
HG268 Tri-angle Gloss Meter | |
Model: | HG268 |
Measuring Angle |
20°/60°/85° Comply with standard ISO 2813, GB/T 9754, ASTM D 523, ASTM D 2457 |
Measuring Area (mm) | 20°: 10x10 60°: 9x15 85°: 5x36 |
Measuring Range | 20°:0~1000GU 60°:0~1000GU 85°:0~160GU |
Division Value | 0.1GU |
Measurement Range Repeatability Reproducibility |
0-10GU 10-100GU 100-1000GU ± 0.1GU ± 0.2GU ± 0.2%GU ± 0.2GU ± 0.5GU ± 0.5%GU |
Measurement Standard | Conform with JJG696 first class glossmeter working requirement |
Chromaticity Corresponding | Corresponding with CIE 1931(2°) under CIE C light source |
Errors | ±1.5 , ± 1.5% |
Measuring Time | 0.1s |
Dimension | L*W*H : 160mm*75mm*90mm |
Weight | 350g |
Language | Chinese/English |
Battery | 3.7V,3200mAh Li-ion Battery ,>10000 times(within 8 hours) |
Display | TFT 3.5 inch |
Interface | USB/RS-232 |
Storage | Basic mode: 1000 |
Software | GQC6 Quality Control Software with QC report printing functions and more extended functions. |
Operation Temperature | 0~40℃(32~104°F) |
Storage Temperature | -20~50℃(-4~122°F) |
Humidity | <85% relative humidity, no condensation |
Standard Accessories | Power Adapter, USB cable, User Manual, GQC6 software CD (except HG60S), Calibration Plate |
Optional Accessories | Miniature Printer |
Note | The specifications are subject to change without notice. |
With 12 rigorous quality inspection processes in place, we ensure a high yield rate of up to 98% for batch processed precision parts.
FAQs About Gloss meter
a. When the colorimeter is disconnected to the PC, "Connection Timeout" will occur. At the moment, you have to check whether the USB cable is well connected the colorimeter and the PC. Then you can re-plug the USB to try out.
b. After ensuring the colorimeter is connected to the PC with USB cable, turn on the colorimeter and enter the main menu. Select "Comm" and press "Enter" key to start communication.
c. Turn off CQCS3 software, and reopen it.
High Measurement Accuracy and Stability: Low ΔE fluctuation (e.g., NH300: ΔE < 0.07; NR10QC: ΔE ≤ 0.03 short-term repeatability); Reliable sensors (CMOS dual-beam/silicon photodiode) and long-lasting light sources (1.6M–3M measurements over 5 years).
User-friendly Design and Convenient Operation: Intuitive interfaces (e.g., NH300’s “fool-proof” operation), auto-calibration, and ergonomic grips for extended use; Versatile positioning (light/cross alignment) for precise measurements.
Robust Design: Our colorimter instruments are designed to withstand rigorous use, providing long-term reliability. Rechargeable lithium batteries enable 5,000–6,000 measurements per charge (e.g., NH300/TS7030), ensuring cost-effective durability.
PC Software Support for Functionality Expansion: PC software (e.g., CQCS3) supports color difference analysis, chromaticity indexing, and sample library management.
Global customer support: Our global presence across regions ensures you get the service and maintenance support you need to keep your instrument at peak performance.
Multiple Measurement Apertures and Application Scenarios: Multiple measurement apertures, different models have different measurement apertures and some models offer multiple optional apertures. Applicable to plastic electronics, paint and ink, textile and garment printing and dyeing, printing, ceramics, automotive, food, medicine and other industries for color quality control and color difference detection.
Who are we? Threnh Technology: 22-Year Professional Color Measurement Solution Provider
Threnh Technology is a Chinese professional manufacturer with 22 years of industry experience, specializing in the field of color measurement and surface gloss detection. Integrating research and development, design, production, marketing, and sales, the company takes technological innovation as its core and is committed to providing global customers with high-precision and intelligent testing instruments as well as professional solutions.
a. If this phenomenon occurred, it means the battery power is not enough. You need to charge the battery.
b. When charge the battery, please insert the battery to the instrument, and plug in the adapter to charge the battery. After 5 minutes, the instrument can be turned on.
c. If the instrument still cannot be turned on after charging 5 minutes, you can pull out the adapter and re-plug in to check it. Or repeat this operation.
d. If the instrument still cannot be turned on after charging 5 minutes, you can turn off the colorimeter and turn on it again to check it. Or repeat this operation.
e. If you have tried all the methods above but the colorimeter still cannot be turned on, please change the battery.
Colorimeter,Gloss meter,Coating thickness meter,window tint meter,UV meter, Leeb hardness tester, Ultrasonic thickness gauge. Threenh Technology company adheres to independent design, research and development, production and sales of various measuring instruments.