Model | YG268 Tri-angle Gloss Meter |
Measuring Angle | 20° 60°85° |
Measuring Area |
20°: 0-2000GU 60°: 0-1000GU 85°: 0-160GU |
Division Value | 0.1GU |
Measuring Modes | Basic mode; Statistic mode; Continuous mode; QC mode |
Measuring Time | 0.5S |
Repeatability | 0~100GU : ±0.2GU; 100~2000GU : ±0.2%GU |
Accurate | Conform with JJG696 first grade requirements of gloss meter |
Auto Power-off Time | Within 30s-120s |
Long-time Calibration | Automatically check and made the calibration |
Language | Chinese & English |
Storage |
35000(Basic mode &Statistic mode : 1500; Continuous mode : 10000; QC mode: 10000) |
Display | 2.3 inch white and black screen |
Size | 160*52*84mm |
Weight | About 300g |
Power Supply | 1pc dry-cell battery(can measure 10000 times) or use USB Charge |
Interface | USB & Bluetooth 2.1 version |
PC Software | GQC6 QC software can printing testing report and with more extended functions |
Operation Temperature Range | 0-40℃(32-104° F) |
Storage Temperature Range | -20-50℃(-4-122° F) |
Humidity Range | < 85% RH, without condensation |
Standard Accessories | USB cable, user manual, calibration plate, QC software |
Optional Accessories | Miniature printer |
Notification: the technical parameter is only for reference |
With 12 rigorous quality inspection processes in place, we ensure a high yield rate of up to 98% for batch processed precision parts.
FAQs About Gloss meter
Yes. We can supply OEM and make customized design for any specific application. Our MOQ for OEM and ODM service is 5 pcs for one model. We can not only offer standard machines, but also customized machines. Don’t hesitate to tell us your requirement, we will try our best to meet your needs.
Opaque liquids and powders can be put into a cuvette for color measurement.
a. Connect colorimeter to the PC with USB cable.
b. Turn on the colorimeter to enter main menu. Select "Comm" and press "Enter" key to start communication.
c. Right click on "My Computer" on the desktop. Click "Manage" -> "Device Manager" -> "Ports", you can see similar display as "SCI USB2Serial (COM6)".
d. Click "Settings->Communication Parameters" in CQCS3 software interface. Select the corresponding port in "Serial Port".
a. It’s needed to perform manual calibration for NH310 when first starting.
b. In the subsequent starting, NH310 will perform auto calibration at startup. No need to perform manual calibration.
c. Suggestion: it’s best to perform manual calibration once a week or when NH310 measured data is not accurate.
a. Users must specify Standard File Name, Sample File Name and Sample Database File Name when first use.
b.Standard File is use to store standard measurement data. Sample File is used to store sample measurement data. Sample Database File is used to store the measured data exported from sample records.