3nh launched new model YD5010 Grating Spectrophotometer Densitometer with 45/0(45 ring-shaped illumination, 0 degree viewing angle), comply to standard ISO 5-4,CIE No.15. It is suitable for using in ink printing, in Film Processing, Textile Printing and Dyeing, Plastic Electronics and Other Industries for Color Measurement and Quality Control;especially suitable for the measurement and quality control of optical density and dot enlargement in ink printing; and it is able to customize single aperture Φ2mm,Φ4mm,Φ8mm.
Under the 45/0 geometric optical illumination and the testing conditions of M O, M 1,M 2 , M 3 stipulated by ISO 13655 standard, the instrument can accurately measure the reflectance data of samples. Under multiple color spaces, it can accurately measure various printing density indexes, color difference formulas and color indexes, and can meet the user's regular testing of various parameters.
1.Perfect combination of the beautiful appearance and the ergonomic structure design;
2.Combined LED light sources with long life and low power consumption, including UV light;
3.Optional apertures: Φ2/4/8mm, adapt to more samples;
4. Accurately measure reflectance spectrum, CMYK density and Lab value of the sample;
5.High-configuration electronic hardware: 3.5-inch TFT true-color screen, capacitive touch screen, concave grating, 256-pixel dual-array CMOS image sensor, etc.;
6.Two standard observer angles: 2/10, multiple light source modes and color systems;
7.USB mode is widely useful;
8.Large-capacity storage space, over 10,000 test data;
9.Especially suitable for process control and quality control of printing plants;
10. PC software has powerful function expansion.
Model | YD5010 |
Measurement Geometry | 45/0(45 ring-shaped illumination, 0 degree viewing angle); ISO 5-4,CIE No.15 |
Features | Common spectrophotometer densitometer, apply in ink printing, in Film Processing, Textile Printing and Dyeing, Plastic Electronics and Other Industries for Color Measurement and Quality Control;especially suitable for the measurement and quality control of optical density and dot enlargement in ink printing;able to customize single aperture Φ2mm,Φ4mm,Φ8mm. |
Light Source | Combined LED Light, UV Light |
Spectral separation device | Concave Grating |
Detector | 256 Image Element Double Array CMOS Image Sensor |
Wavelength Range | 400~700nm |
Wavelength Pitch | 10nm |
Half Bandwidth | 10nm |
Measurement Conditions |
Compliance with ISO 13655 measurement conditions; M0 (CIE Light Soure A) M1 (CIE Light Soure D50) M2 (Excluding UV light source) M3 (M2+Polarized light filter) |
Density Standards | ISO Status A, E, I, T |
Density index | Density value, density difference, dot area, dot enlargement, overprint, printing characteristics, printing contrast, tone error and gray level |
Measurement aperture | Customized one aperture:Φ2mm,Φ4mm,Φ8mm optional |
Color Spaces | CIE LAB,XYZ,Yxy,LCh |
Color Difference Formula | ΔE*ab,ΔE*94,ΔE*00 |
Other Colorimetric Index | / |
Observer Angle | 2°/10° |
Illuminants | A,C,D50,D55,D65,D75,F2,F7,F11,F12 |
Measurement Time | About 1.5s |
Repeatability | Density: Within 0.01 D |
Chromaticity value:within ΔE*ab 0.04 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) Except M3 | |
Inter-instrument Error | Within ΔE*ab 0.2 (Average for 12 BCRA Series II color tiles) Except M3 |
Measurement mode | Single Measurement, Average Measurement(2-99) |
Size(L*W*H) | 184*77*105mm |
Weight | About 600g |
Power source | Li-ion battery. 5000 measurements within 8 hours |
Illuminant Life Span | 5 years, more than 3 million times measurements |
Display | 3.5-inch TFT color LCD, Capacitive Touch Screen |
Interface | USB, |
Data memory | 10000 pcs |
Language |
Simplified Chinese, English, Traditional Chinese |
Working Environment | Temperature: 0~40℃; Humidity: 0~85% (No Condensation);altitude: less than 2000 m |
Storage Environment | Temperature: -20~50℃; Humidity: 0~85% (No Condensation)) |
Standard Accessory | Power Adapter, USB Cable, Built-in li-ion battery, User Manual, software(download from the website),White and Black Calibration Board, Protective Cover,Polarization filter box,Locating Plate |
Optional Accessory | Micro Printer |
Notes: The specifications are subject to change without notice. |
With 12 rigorous quality inspection processes in place, we ensure a high yield rate of up to 98% for batch processed precision parts.
FAQs About Spectrodensitometer
At most of time, we have stock in the factory. Generally it is 1-3 working days after the payment confirmed. After shipped, we will email you the tracking number. You can check the shipping status of your order on the website. If you are in urgent need, we can consider making special arrangement for you.
You can choose a colorimters depending on the substrate you are measuring the color of, whether it is opaque, translucent or transparent. In short, you can consider the following factors for choosing the right 3NH colorimeter for your needs: Sample Opacity, Physical Form, Optical Properties needed, Measurement Methods required, Scales and Indices needed, Instrument Standards Conformance (ASTM/ISO/Other), Instrument Geometry, Instrument Performance, Location (laboratory, portability, in-process) and Sample Handling requirements.
By systematically addressing these factors, you can select a colorimeter that optimizes accuracy, efficiency, and value for your specific application.Learn more from our ultimate guide on colorimeter selection. If unsure, consult the 3NH manufacturer for personalized recommendations based on your sample and workflow.
A colorimeter is a scientific instrument used to measure and analyze the color characteristics of objects or materials. It quantifies color by evaluating specific parameters related to human visual perception and standardized color spaces.
a. If this phenomenon occurred, it means the battery power is not enough. You need to charge the battery.
b. When charge the battery, please insert the battery to the instrument, and plug in the adapter to charge the battery. After 5 minutes, the instrument can be turned on.
c. If the instrument still cannot be turned on after charging 5 minutes, you can pull out the adapter and re-plug in to check it. Or repeat this operation.
d. If the instrument still cannot be turned on after charging 5 minutes, you can turn off the colorimeter and turn on it again to check it. Or repeat this operation.
e. If you have tried all the methods above but the colorimeter still cannot be turned on, please change the battery.
Our machine is packed by standard export wooden box, it won’t be damaged. We’ve delivered many testing machines abroad by sea or by air without damage.