Order No. | Name | Model | D65 | TL84/U30 | F/A | UV | CWF | Voltage |
10103 | Standard light source box | M60 five light source(220V) | 2 pcs | 1 pcs | 4 pcs | 1 pcs | 1 pcs | 220V/50Hz |
10803 | Standard light source box | M60 five light source(115V) | 2 pcs | 1 pcs | 4 pcs | 1 pcs | 1 pcs | 115V/60Hz |
Light Source | Color viewing booths application | Color temperature(k) | Power(W) | Brand&Specification |
D65 | International standard Artificial Daylight | 6500 | 20 | Gretagmacbeth F20T12/65 |
TL84 | Applied to stores in EuropeJapan and China | 4000 | 18 |
PHILIPS TLD 18W/840 |
CWF | (Cool White Fluorescent)American Standard | 4150 | 18 |
SYLVANIA F20T12/CW |
TL83 | Warm White Fluorescent American Standard | 3000 | 18 |
PHILIPS TLD 18W/830 |
F | "Sun-setting Light Yellow" incandescent light source(imitation of sunset) | 2700 | 40 |
3nh 40W |
A | American shopwindow spotlight | 2700 | 40 |
3nh 60W |
UV | Viewing under ultraviolet light to detect and evaluate optical brighteners or fluorescent pigments | Wavelength:365nm | 20 |
PHILIPS TLD 18W/BLB |
With 12 rigorous quality inspection processes in place, we ensure a high yield rate of up to 98% for batch processed precision parts.
FAQs About Light Booth
A colorimeter is a scientific instrument used to measure and analyze the color characteristics of objects or materials. It quantifies color by evaluating specific parameters related to human visual perception and standardized color spaces.
After receiving NH310/NH300, you have to perform white and black calibration manually when first starting.
a. If this phenomenon occurred, it means the battery power is not enough. You need to charge the battery.
b. When charge the battery, please insert the battery to the instrument, and plug in the adapter to charge the battery. After 5 minutes, the instrument can be turned on.
c. If the instrument still cannot be turned on after charging 5 minutes, you can pull out the adapter and re-plug in to check it. Or repeat this operation.
d. If the instrument still cannot be turned on after charging 5 minutes, you can turn off the colorimeter and turn on it again to check it. Or repeat this operation.
e. If you have tried all the methods above but the colorimeter still cannot be turned on, please change the battery.
High Measurement Accuracy and Stability: Low ΔE fluctuation (e.g., NH300: ΔE < 0.07; NR10QC: ΔE ≤ 0.03 short-term repeatability); Reliable sensors (CMOS dual-beam/silicon photodiode) and long-lasting light sources (1.6M–3M measurements over 5 years).
User-friendly Design and Convenient Operation: Intuitive interfaces (e.g., NH300’s “fool-proof” operation), auto-calibration, and ergonomic grips for extended use; Versatile positioning (light/cross alignment) for precise measurements.
Robust Design: Our colorimter instruments are designed to withstand rigorous use, providing long-term reliability. Rechargeable lithium batteries enable 5,000–6,000 measurements per charge (e.g., NH300/TS7030), ensuring cost-effective durability.
PC Software Support for Functionality Expansion: PC software (e.g., CQCS3) supports color difference analysis, chromaticity indexing, and sample library management.
Global customer support: Our global presence across regions ensures you get the service and maintenance support you need to keep your instrument at peak performance.
Multiple Measurement Apertures and Application Scenarios: Multiple measurement apertures, different models have different measurement apertures and some models offer multiple optional apertures. Applicable to plastic electronics, paint and ink, textile and garment printing and dyeing, printing, ceramics, automotive, food, medicine and other industries for color quality control and color difference detection.
a. It’s needed to perform manual calibration for NH300 when first starting.
b. In the subsequent starting, no need to perform manual calibration.
c. Suggestion: it’s best to perform manual calibration once a week or when NH300 measured data is not accurate.