TS7708 Grating Spectrometer
The TS7708 spectrometer, a product of 3NH's three - year dedicated R&D, It features a 1000 - line precision blazed grating for light splitting and a double - row 40 - group silicon photodiode array sensor. This large - area sensor ensures no saturation under strong light, high sensitivity to weak light, and a broad spectral response, guaranteeing fast, accurate, stable, and consistent measurements.
Key Highlights
1000 - line precision blazed grating for light splitting and a double - row 40 - group silicon photodiode array sensor
D/8 geometric optical illumination
Measure SCI and SCE reflectance data for both regular and fluorescent samples
Repeatability (ΔEab ≤ 0.03) and inter - instrument error (ΔEab ≤ 0.15)
Three measuring apertures (φ8mm, φ4mm, 1x3mm)
D/8 (SCI/SCE) measurement structure, compliant with multiple international standards
Widely used in plastic electronics, paint coatings, textile printing and dyeing, printing, automotive, medical, cosmetics, and food industries
TS7X series grating spectrophotometer is 3NH company spent 3 years, carefully designed, fully with independent intellectual property rights grating spectrophotometer. The instrument uses 1000 lines of precision shining grating as the optical splitter, built-in silicon photodiode array (double row 40 groups) sensor, imported white board, repeatability delta E* AB easily controlled within 0.03, the use of long life full spectrum LED as the light source, optical resolution in the visible range is less than 10nm.
Under the condition of d/8 geometric optical illumination recommended by CIE, TS7700 grating spectrophotometer can accurately measure the SCI and SCE reflectance data of samples / fluorescent samples, and also can accurately measure and express various color difference formulas and color indexes in various color spaces. With spectrophotometer TS7700, it can easily realize the accurate transmission of color and can also be used as the detection equipment of accurate color matching system.
TS7708 spectrometer is equipped with φ 8mm, φ 4mm, 1x3mm three measuring apertures, more adaptability, accurate measurement of color, stable performance, in plastic electronics, paint coating, textile printing and dyeing, printing paper products, automotive, medical, cosmetics and food industries, in scientific research institutions, laboratory fields are widely used.
Technical Advantages:
1. Silicon photodiode array (double 40 array) sensor
The larger area of the double 40 array sensor, the strong light will not saturation, weak light sensitivity and a wider spectrum response range, to ensure the instrument measurement speed, accuracy, stability and consistency, master the core technology, and the international standard of the same platform, complete compatibility.
2. Adopt full waveband balanced LED light source
The full waveband balanced LED light source ensures sufficient spectral distribution in the visible light range, avoids the spectral loss of white LED in specific waveband, and ensures the measurement speed and accuracy of the measurement results.
3. Grating spectroscopic technique
Use Grating spectroscopic technique, with higher resolution, to make the color measurement more accurate.
4. Place the base safely to ensure that the whiteboard is not dirty.
5. Professional whiteboard, a lifetime never change color commitment
6. Fast charging
Special fast charging mode, low voltage to remind charging or use off-duty time charging, to ensure the capacity and life of the battery (note: frequent repeated battery charging more harm).
7. New fashionable appearance design based on ergonomics
The position of the hand holding and the measurement button are carefully designed to meet different holding habits, smooth and fine surface, resulting from the high-precision appearance processing art.
8. Equipped with three measuring apertures to meet the most samples measurement
The Factory configuration of spectrophotometer TS7708 is with ø 8mm flat aperture, ø 8mm tip aperture, ø 4mm flat aperture, ø 4mm tip aperture, ø 1x3mm aperture, a total of five measuring apertures, to meet the most samples measurement.
9. Camera positioning can clearly observe the measured area
Spectrophotometer TS7708 built-in camera positioning, through the camera real-time view, can accurately determine whether the object measured part is the target center, improve the measurement efficiency and accuracy.
10. Excellent errors between instruments and repeatability
Ensure the consistency of measurement data of multiple equipment, to be used for color matching and accurate color transfer.
11. A variety of color spaces and observation light sources
Offer CIE LAB,XYZ,Yxy,LCh,CIE LUV, S-RGB,HunterLab,βXY,DIN Lab99 Munsell(C/2) color spaces, and D65, A, C, D50, D55, D75, F1, F2 (CWF), F3, F4 and F5, F6 and F7 (DLF), F8, F9, F10 (TPL5), and F11 (TL84), F12 (TL83 / U30) a variety of light sources, to meet the special measurement requirements under different measurement conditions.
12. Adopt international common use d/8 SCI/SCE Synthesis technology
Adopt D/8 (SCI/SCE) measurement structure to more objectively reflect the color itself, and reduce the impact of object surface texture on test results, in accordance with CIE No.15. GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7.
13. Dual optical path system for more accurate color measurement
Dual optical path system, optical resolution is less than 10nm in the visible range, can simultaneously measure the sample SCI, SCE spectrum.
14. PC software has powerful function expansion
SQCX quality management software with TS7708 spectrophotometer is suitable for quality monitoring and color data management of various industries. Digitize user data color management.
Specification
Model | TS7708 |
Optical Geometry |
D/8 (diffused illumination, 8-degree viewing angle) SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source Conforms to CIE No.15, GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7 |
Characteristic |
3 measuring apertures for accurate color analysis and transmission in laboratory It is used for precise color measurement and quality control in plastic electronics, paint and ink, textile and garment printing and dyeing, printing, ceramics and other industries, and for fluorescent sample measurement. |
Integrating Sphere Size | Φ40mm |
Light Source | Combined full spectrum LED light source, UV light source |
Spectrophotometric Mode | Flat Grating |
Sensor | Silicon photodiode array (double row 40 groups) |
Wavelength Range | 400~700nm |
Wavelength Interval | 10nm |
Semiband Width | 10nm |
Measured Reflectance Range | 0-200% |
Measuring Aperture |
3 apertures: MAV:Φ8mm/Φ10mm;SAV:Φ4mm/Φ5mm;LAV:1x3mm LAV1x3mm: Slightly poor accuracy, can be used for color test |
Specular Component | SCI&SCE |
Color Space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,s-RGB,HunterLab,βxy,DIN Lab99 Munsell(C/2) |
Color Difference Formula | ΔE*ab,ΔE*uv,ΔE*94 ,ΔE*cmc(2:1),ΔE*cmc(1:1) ,ΔE*00, DINΔE99, ΔE(Hunter) |
Other Colorimetric Index | Spectrum Reflectance Rate, WI(ASTM E313-00,ASTM E313-73,CIE/ISO,AATCC,Hunter,TaubeBergerStensby), YI(ASTM D1925,ASTM E313-00,ASTM E313-73) Metamerism Index Mt, Staining Fastness, Color Fastness, Strength (dye strength, tinting strength), Opacity 8-degree Gloss, 555 Index,Blackness(My,dM), Color Density CMYK(A,T,E,M), Tint(ASTM E313-00),Munsell(Some functions are realized through the computer) |
Observer Angle | 2°/10° |
Illuminant | D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5),F11(TL84),F12(TL83/U30),B,U35,NBF, ID50,ID65,LED-B1,LED-B2,LED-B3,LED-B4,LED-B5,LED-BH1,LED-RGB1,LED-V1,LED-V2,LED-C2,LED-C3,LED-C5, Light source can be customized(a total of 41 kinds of light sources, some of which are realized through the host computer/APP) |
Displayed Data | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset |
Measuring Time | About 1.5s (Measure SCI & SCE about 3.2s) |
Repeatability |
Spectral reflectance: MAV/SCI, Standard deviation within 0.08% (400 nm to 700 nm: within 0.18%) Chromaticity value: MAV/SCI, within ΔE*ab 0.03 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) |
Inter-instrument Error |
MAV/SCI, Within ΔE*ab 0.15 (Average for 12 BCRA Series II color tiles) |
Measurement Mode | Single Measurement, Average Measurement(2-99times) |
Locating Method | Camera Locating,stabilizer cross position |
Dimension | L*W*H=129X76X217mm |
Weight | Approx 600g |
Battery | Li-ion battery, 6000 measurements within 8 hours |
Illuminant Life Span | 5 years, more than 3 million times measurements |
Displayed Data | 3.5-inch TFT color LCD, Capacitive Touch Screen |
Data Port | USB, Bluetooth 5.0 |
Data Storage | Standard 1000 Pcs, Sample 30000 Pcs |
Language | Simplified Chinese, English, traditional Chinese,Russian |
Operating Environment | 0~40℃, 0~85%RH (no condensing), Altitude < 2000m |
Storage Environment | -20~50℃, 0~85%RH (no condensing) |
Standard Accessory | Power Adapter, User Guide, PC Software(Download from office website), USB cable, White and Black Calibration Cavity, Protective Cover, Wrist strap, 8mm flat aperture, 8mm tip aperture, 4mm flat aperture, 4mm tip aperture,1x3mm tip aperture |
Optional Accessory | Micro Printer, Powder Test Box, Holding base |
Notes | The specifications are subject to change without notice. |
With 12 rigorous quality inspection processes in place, we ensure a high yield rate of up to 98% for batch processed precision parts.
FAQs About Spectrophotometer
a. If this phenomenon occurred, it means the battery power is not enough. You need to charge the battery.
b. When charge the battery, please insert the battery to the instrument, and plug in the adapter to charge the battery. After 5 minutes, the instrument can be turned on.
c. If the instrument still cannot be turned on after charging 5 minutes, you can pull out the adapter and re-plug in to check it. Or repeat this operation.
d. If the instrument still cannot be turned on after charging 5 minutes, you can turn off the colorimeter and turn on it again to check it. Or repeat this operation.
e. If you have tried all the methods above but the colorimeter still cannot be turned on, please change the battery.
You can choose a colorimters depending on the substrate you are measuring the color of, whether it is opaque, translucent or transparent. In short, you can consider the following factors for choosing the right 3NH colorimeter for your needs: Sample Opacity, Physical Form, Optical Properties needed, Measurement Methods required, Scales and Indices needed, Instrument Standards Conformance (ASTM/ISO/Other), Instrument Geometry, Instrument Performance, Location (laboratory, portability, in-process) and Sample Handling requirements.
By systematically addressing these factors, you can select a colorimeter that optimizes accuracy, efficiency, and value for your specific application.Learn more from our ultimate guide on colorimeter selection. If unsure, consult the 3NH manufacturer for personalized recommendations based on your sample and workflow.
Always a pre-production sample before mass production; Always final Inspection before shipment;
a. Users must specify Standard File Name, Sample File Name and Sample Database File Name when first use.
b.Standard File is use to store standard measurement data. Sample File is used to store sample measurement data. Sample Database File is used to store the measured data exported from sample records.
At most of time, we have stock in the factory. Generally it is 1-3 working days after the payment confirmed. After shipped, we will email you the tracking number. You can check the shipping status of your order on the website. If you are in urgent need, we can consider making special arrangement for you.