YH1100 Haze Meter

This YH1100 Haze Meter Instrument are Certified with
certify
1 Years Warranty (Additional support period of 3 years)

YH1100 haze meter can easily achieve ASTM D1003 non-compensation method, full light transmittance,haze test.Open sample bin can be vertically and horizontally tested to accommodate more samples to be tested.The YH1100 haze meter uses a PDF array detector to meet the CIE V(λ)2 degree visual response. The compensation method can be used to measure the light transmittance and haze with high precision and repeatability.

Technical Advantage

1.Double standard  ASTM

Able to meet the test standard requirements of different users, in accordance with ASTM D1003/1044,GB/T 2410,JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136

2.Easy to operate, faster and more accurate measurement

The YH1100 haze meter is equipped with a large-size touch screen for easy operation.With a PD array detector, CIE V(λ)2 degree visual response enables high precision and repeatable transmittance and fog measurements.USB data output device for docking with laboratory system.

3.Dynamic measurement

Independent light source detector and temperature sensor, constantly monitor light source and environmental change, ensure the reliability of test data.

4.Easy to measure and widely applicable to samples

Open measuring area, vertical and horizontal testing, suitable for more samples to be tested.

5.Quality control software

It provides powerful software for measuring and analyzing fog and light transmittance, which is suitable for quality monitoring and tabulated management of fog and light transmittance data in various industries.The management of users will be digitized at the PC end, the difference of fog and light transmittance will be compared, and the test report form will be generated to facilitate customer customization and management.

Application

YH1100 haze meter is widely used in glass processing, plastic processing, film processing, screen processing, packaging industry, liquid pharmaceutical analysis and other aspects.

 

Product Model  YH1100 Haze Meter
Optical Geometry Transmittance:0/D(Parallel light illumination, diffuse viewing)
Conforms to:ASTM D1003/1044,GB/T 2410,JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136
Character The instrument can easily achieve ASTM D1003 non-compensation method, full light transmittance,haze test. Open measuring area for vertical and horizontal testing. In glass processing, plastic processing, film, screen processing, packaging and other industries are widely used in transmittance,haze detection.
Integrating Sphere Size Φ154mm
Light Source 400nm to 700nm, combined LED light
Specular Component /
Sensor The PD array detector satisfies CIE V(λ)2 degree visual response
Wavelength Range /
Wavelength Interval /
Semiband Width /
Transmittance measurement range 0~100%
Measuring Aperture Φ20mm/Φ15mm/Φ8mm/Φ4mm(Select a single aperture)
Sample Size Thickness <170mm
Color Space /
Color Difference Formula /
Other Colorimetric Index Haze(ASTM D1003/1044,ISO 13468),Transmittance T(ASTM)
Observer Angle
Illuminant D65,A,C
Displayed Data PASS/FAIL Result
Measuring Time About1.5s
Haze resolution 0.01unit
Haze repeatability Φ20mm,within 0.1(After preheating and calibration of the instrument, standard deviation values of standard haze tablets with a test haze of about 40 for 30 times were taken at intervals of 5s.)
Inter-instrument Error Φ20mm,with 0.4(After the instrument is preheated and calibrated, the standard deviation between the standard haze tablet and the reference value is tested at an interval of 5s.)
Dimension L*W*H=290X211X511mm
Weight About7.6kg
Power AC 24V, 3A Power adapter power supply
Illuminant Life Span 5 years, more than 3 million times measurements
Display 7-inch TFT color LCD, Capacitive Touch Screen
Data Port USB & Print serial port
Data Storage Standard 1000 pcs,sample 20000 pcs
Language Simplified Chinese,Traditional Chinese,English
Operating Environment 0~40℃(32~104°F)
Storage Environment  -20~50℃(-4~122°F)
Standard Accessory Power Adapter, User Guide,Quality Management Software (download from the official website),USB cable,0% calibration box,Aperture.
Optional Accessory Micro-printer,Test fixture, standard haze sheet, foot switch
Note: The specifications are subject to change without notice.

12 Quality Inspection Processes

With 12 rigorous quality inspection processes in place, we ensure a high yield rate of up to 98% for batch processed precision parts.

DFM Analysis
DFM Analysis
Dimensional Tolerance
Dimensional Tolerance
Material Testing
Material Testing
CNC Machining
CNC Machining
FQC Detection
FQC Detection
SPC / CPK
SPC / CPK
Problem Found
Problem Found
Problem Solving
Problem Solving
OQC Detection
OQC Detection
Surface Treatment
Surface Treatment
Full Inspection
Full Inspection
Package
Package

FAQs About Haze Meters

a. It’s needed to perform manual calibration for NH310 when first starting.

b. In the subsequent starting, NH310 will perform auto calibration at startup. No need to perform manual calibration.

c. Suggestion: it’s best to perform manual calibration once a week or when NH310 measured data is not accurate.

a. If this phenomenon occurred, it means the battery power is not enough. You need to charge the battery.

b. When charge the battery, please insert the battery to the instrument, and plug in the adapter to charge the battery. After 5 minutes, the instrument can be turned on.

c. If the instrument still cannot be turned on after charging 5 minutes, you can pull out the adapter and re-plug in to check it. Or repeat this operation.

d. If the instrument still cannot be turned on after charging 5 minutes, you can turn off the colorimeter and turn on it again to check it. Or repeat this operation.

e. If you have tried all the methods above but the colorimeter still cannot be turned on, please change the battery.

Our professional team will give you the best suggestion as long as you tell us what kind of test you need to do and the required specification.


a. Check whether the USB cable is connected. If not, please connect it. Check whether the connection is effective. You can re-plug the USB cable to test.

b. If the USB cable is connected well but the interface still displays "USB Disconnect", please re-start the colorimeter and enter "Menu" -"Comm"to start the communication.

c. Change the USB cable or change the USB port in you PC.

After receiving NH310/NH300, you have to perform white and black calibration manually when first starting.

Related Haze Meters You May Also Like