NS800 spectrophotometer uses the principle of combination LED precision spectroscopy, separates the light according to a certain wavelength interval, and adopts groups of sensor array to perform sensitive analysis. NS800 spectrophotometer with higher accuracy is very sensitive to any colors. It not only can measure L*ab value and delta E value accurately, but also can display spectral reflectance curve which can realize color matching function and calculate the real parameters of various color formulas.
In the R&D process, 3nh scientists and engineers measured various color samples from dark to light, white to black, and other standard color boards provided by ISO (International Standardization Organization). The parameters of test results are integrating with international standards.
3nh also analyzed the parameters from Japan, American and Germany spectrophotometers. The differences of L*ab absolute value between them are within ±1.5. Compared the L*ab value between NS800 and Japan spectrophotometer, when measuring any color objects, the biggest L*ab difference is within ±1.0. This is a breakthrough of 3nh high technology which realizes to be fully compatible with international market.
Model | NS800 |
Illumination/observation system | 45/0 method (45 ring-shaped illumination, vertical viewing), Comply with CIE No.15,GB/T 3978 |
Integrating sphere Size | Φ58mm |
Light Source | combined LED sources |
Sensor | Silicon photodiode array |
Wavelength range | 400~700nm |
Wavelength interval | 10nm |
Reflectance range | 0~200% |
Measuring Aperture | Φ8mm |
Color Space | CIE LAB,XYZ,Yxy,LCh,CIE LUV |
Color difference Formula | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1), ΔE*cmc(1:1),ΔE*00 |
Other Chromaticity Data | WI(ASTM E313,CIE/ISO, AATCC, Hunter), YI(ASTM D1925,ASTM 313), TI(ASTM E313,CIE/ISO), Metamerism Index (Mt), Color Stain, Color Fastness |
Observer | 2°/10° |
Illuminant | D65,A,C,D50,D55,D75,F2,F6,F7,F8,F10,F11,F12 |
Display Data | Spectral Value/Graph, Colorimetric Value, Color Difference Value/Graph, PASS/FAIL Result, Color Offset, Color Simulation |
Measurement Time | 1.5s |
Repeatability | Spectral Reflectance: standard deviation within 0.1%(400~700nm: within 0.2%) |
Colorimetric Value | Standard deviation within Delta E*ab 0.04 (Measurement conditions: white calibration plate measured 30 times at 5 seconds intervals after white calibration was performed.) |
Inter Instrument Agreement | Within Delta E*ab 0.2 (Average for 12 BCRA Series II color tiles) |
Dimension | L*W*H=90*77*230mm |
Weight | 600g |
Battery | Li-ion battery. 5000 times within 8 hours |
Lamp Life | 5 years, more than 1.6 million measurements |
Display Screen | TFT 3.5inch, Capacitive Touch Screen |
Interface | USB/RS-232 |
Data Memory | 1000 Standards, 15000 Samples |
Operating Temperature | 0~40℃(32~104°F) |
Storage temperature | -20~50℃(-4~122°F) |
Standard Accessory | Power Adapter, Li-ion Battery, Operating Instruction, CD-ROM (containing management software), Data Line, White and Black Calibration Cavity, Protective Cover and Wrist Strap |
Optional Accessory | Micro Printer, Universal Test Compon |
Others |
Provide complete spectrum reflectance curve, Input L, a, b value manually |
Notes | The specifications are subject to change without notice |
With 12 rigorous quality inspection processes in place, we ensure a high yield rate of up to 98% for batch processed precision parts.
FAQs About Spectrophotometer
Yes, we can offer quality certification issued by our lab free of charge, or issued by third-party international inspection Organizations with extra charge, please contact us for confirmation.
There are three measuring apertures for NH310: Φ8mm (standard accessory), Φ4mm (standard accessory), extended Φ8mm (optional accessory)
a. Turning on
b. Removing measuring aperture, install the needed measuring aperture.
c. Select "Settings-Aperture Setting" in main menu to select corresponding measuring aperture.
d. After selecting aperture, the instrument will display "White and Black Calibration" interface. White and black calibration must be performed.
e. Replace completed.
a. If this phenomenon occurred, it means the battery power is not enough. You need to charge the battery.
b. When charge the battery, please insert the battery to the instrument, and plug in the adapter to charge the battery. After 5 minutes, the instrument can be turned on.
c. If the instrument still cannot be turned on after charging 5 minutes, you can pull out the adapter and re-plug in to check it. Or repeat this operation.
d. If the instrument still cannot be turned on after charging 5 minutes, you can turn off the colorimeter and turn on it again to check it. Or repeat this operation.
e. If you have tried all the methods above but the colorimeter still cannot be turned on, please change the battery.
Yes. We can supply OEM and make customized design for any specific application. Our MOQ for OEM and ODM service is 5 pcs for one model. We can not only offer standard machines, but also customized machines. Don’t hesitate to tell us your requirement, we will try our best to meet your needs.
A colorimeter is a scientific instrument used to measure and analyze the color characteristics of objects or materials. It quantifies color by evaluating specific parameters related to human visual perception and standardized color spaces.