Perfect Partner for Color Measurement YS3010
YS3010 Grating spectrophotometer developed by 3nh independently, features with stable performance, precise measurement and powerful functions in leading position of same industry. YS3010 Economic Spectrophotometer Cost-effective, four kinds of most widely used lluminants, 8mm aperture, SCI/SCE, good accuracy, large storage capacity, meet most needs.
Key Highlights
D/8 geometrical optics, conforms to CIE No.15,GB/T3978,GB2893...
Reliable repeatability ( ΔE*≤0.06) and inter-instrument agreement (ΔEab ≤0.4)
Single 8/4mm aperture, SCI & SCE together
Accurate spectra &Lab data , for color matching & delivery
Combined LED light source, excluding UV
High configuration:3.5-inch TFT color LCD,Capacitive Touch Screen
Large storage capacity , Apprx. 20,000 data;
YS30 Series grating spectrophotometer adopts bluetooth and USB dual modes for wider use, and with SCI & SCE measurement data, it is compatible with many famous brands. 8mm, 4mm or customized aperture is optional. Speical UV light makes YS3060 easy to measure sample with UV and high accuracy and extended function PC software let it be good partner for colorist and color quality contral management.
YS3060 UV Grating Spectrophotometer
Full Illuminants + UV, 8mm&4mm Apertures, SCI&SCE, Bluetooth Comm, High Precision.
YS3020 Grating Spectrophotometer
Multi-illuminants, Customizable Aperture, SCI&SCE, Bluetooth Comm, High Precision.
YS3010 Grating Spectrophotometer
4 Illuminants, 8mm Aperture, SCI&SCE, Good Precision.
Comply with CIE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724/1,ASTM E1164,DIN5033 Teil7, YS3010 color spectrophotometer features only 8mm single aperture. Both SCI and SCE mode makes it widely use in many applications. It has high accuracy 0.06 based on white calibration plate measured 30 times at 5 seconds intervals after white calibration was performed.
Features
A.Perfect combination of beautiful appearance and the human body mechanics structural design;
B.D/8 geometrical optics, conforms with CIE No.15,GB/T 3978,GB2893, GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil
C.Use long life and low power consumption combined LED light source
D.Single 8mm aperture, support both SCI and SCE at the same time;
E.Measure sample spectra, accurate Lab data , can be used in color matching and accurate color transmission;
F.High electronic hardware configuration: 3.5-inch TFT color LCD,Capacitive Touch Screen, concave grating, 256 Iimage Element Double Arrays CMOS Image Sensor;
G.USB port, widely useful;
H.Super stain-resistant and stable standard white calibration plate;
I.Large capacity storage space, over 20,000 measurement data;
J.Two standard observer angles, a variety of illuminant, a variety of color indexes, conforms with a variety of standard colorimetric data, meet a variety of customers' demand for color measurement;
K.Camera Locating Function, better position;
l.PC software has a powerful function extension.
Model Items | YS3060 | YS3020 | YS3010 |
Optical Geometry | Reflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle) | ||
Integrating Sphere Size | 48mm | ||
Light Source | Combined LED Light, UV Light | Combined LED Light | |
Spectrophotometric Mode | Concave Grating | ||
Sensor | 256 Image Element Double Array CMOS Image Sensor | ||
Wavelength Range | 400-700nm | ||
Wavelength Interval | 10nm | ||
Semiband Width | 10nm | ||
Measured Reflectance Range | 0-200% | ||
Measuring Aperture | Dual Aperture: 10mm/8mm & 5mm/4mm | Customized Aperture: 8mm/4mm/1×3mm | Single Aperture: 8mm/10mm |
Specular Component | SCI&SCE | ||
Color Space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,s-RGB,HunterLab,βxy,DIN Lab99 Munsell(C/2) | ||
Color Difference Formula | ΔE*ab,ΔE*uv,ΔE*94 ,ΔE*cmc(2:1),ΔE*cmc(1:1) ,ΔE*00, DINΔE99, ΔE(Hunter) | ||
Other Colorimetric Index | Spectrum Reflectance Rate, WI(ASTM E313-00,ASTM E313-73,CIE/ISO,AATCC,Hunter,TaubeBergerStensby), YI(ASTM D1925,ASTM E313-00,ASTM E313-73) Metamerism Index Mt, Staining Fastness, Color Fastness, Strength (dye strength, tinting strength), Opacity 8-degree Gloss, 555 Index,Blackness(My,dM), Color Density CMYK(A,T,E,M), Tint(ASTM E313-00),Munsell(Some functions are realized through the computer) | ||
Observer Angle | 2°/10° | ||
Illuminant | D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5),F11(TL84),F12(TL83/U30),B,U35,NBF, ID50,ID65,LED-B1,LED-B2,LED-B3,LED-B4,LED-B5,LED-BH1,LED-RGB1,LED-V1,LED-V2,LED-C2,LED-C3,LED-C5, Light source can be customized(a total of 41 kinds of light sources, some of which are realized through the host computer/APP) | ||
Displayed Data | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset | ||
Measuring Time | 2.6s | ||
Repeatability | MAV/SCI: ΔE*≤0.03 | MAV/SCI: ΔE*≤0.05 | MAV/SCI: ΔE*≤0.06 |
Inter-instrument Error | MAV/SCI: ΔE*≤0.15 | MAV/SCI: ΔE*≤0.2 | MAV/SCI: ΔE*≤0.4 |
Measurement Mode | Single Measurement, Average Measurement | ||
Locating Method | Camera View Finder Locating | ||
Battery | Li-ion battery. 5000 measurements within 8 hours | ||
Dimension | L*W*H=184*77*105mm | ||
Weight | 600g | ||
Illuminant Life Span | 5 years, more than 3 million times measurements | ||
Display | 3.5-inch TFT color LCD, Capacitive Touch Screen | ||
Data Port | USB, Bluetooth 5.0 | ||
Data Storage | Standard 1000 Pcs, Sample 20000 Pcs | Standard 800 Pcs, Sample 20000 Pcs | |
Language | Chinese Simplified, Chinese Traditional, English, French, Portuguese, Russian, Spanish, Italian, German | ||
Operating Environment | 0~40℃, 0~85%RH (no condensing), Altitude < 2000m | ||
Storage Environment | -20~50℃, 0~85%RH (no condensing) | ||
Standard Accessory | Power Adapter, Built-In Li-ion Battery, User Guide, PC Software, White and Black Calibration Cavity, Dust Cover | ||
Optional Accessory | Micro Printer, Powder Test Box | ||
Notes: The specifications are subject to change without notice. |
Application Industry
3nh handheld spectrophotometer can easily achieve color transferring , and be used as a precision instrument for color matching system. It's widely used in plastics, electronics, painting, ink, textile and garment, printing and dyeing, printing paper, automotive, medical, cosmetics and food industries, scientific research institutes, schools and laboratories.
Package Image
With 12 rigorous quality inspection processes in place, we ensure a high yield rate of up to 98% for batch processed precision parts.
FAQs About Spectrophotometer
High Measurement Accuracy and Stability: Low ΔE fluctuation (e.g., NH300: ΔE < 0.07; NR10QC: ΔE ≤ 0.03 short-term repeatability); Reliable sensors (CMOS dual-beam/silicon photodiode) and long-lasting light sources (1.6M–3M measurements over 5 years).
User-friendly Design and Convenient Operation: Intuitive interfaces (e.g., NH300’s “fool-proof” operation), auto-calibration, and ergonomic grips for extended use; Versatile positioning (light/cross alignment) for precise measurements.
Robust Design: Our colorimter instruments are designed to withstand rigorous use, providing long-term reliability. Rechargeable lithium batteries enable 5,000–6,000 measurements per charge (e.g., NH300/TS7030), ensuring cost-effective durability.
PC Software Support for Functionality Expansion: PC software (e.g., CQCS3) supports color difference analysis, chromaticity indexing, and sample library management.
Global customer support: Our global presence across regions ensures you get the service and maintenance support you need to keep your instrument at peak performance.
Multiple Measurement Apertures and Application Scenarios: Multiple measurement apertures, different models have different measurement apertures and some models offer multiple optional apertures. Applicable to plastic electronics, paint and ink, textile and garment printing and dyeing, printing, ceramics, automotive, food, medicine and other industries for color quality control and color difference detection.
a. Connect colorimeter to the PC with USB cable.
b. Turn on the colorimeter to enter main menu. Select "Comm" and press "Enter" key to start communication.
c. Right click on "My Computer" on the desktop. Click "Manage" -> "Device Manager" -> "Ports", you can see similar display as "SCI USB2Serial (COM6)".
d. Click "Settings->Communication Parameters" in CQCS3 software interface. Select the corresponding port in "Serial Port".
a. When the colorimeter is disconnected to the PC, "Connection Timeout" will occur. At the moment, you have to check whether the USB cable is well connected the colorimeter and the PC. Then you can re-plug the USB to try out.
b. After ensuring the colorimeter is connected to the PC with USB cable, turn on the colorimeter and enter the main menu. Select "Comm" and press "Enter" key to start communication.
c. Turn off CQCS3 software, and reopen it.
a. It’s needed to perform manual calibration for NH300 when first starting.
b. In the subsequent starting, no need to perform manual calibration.
c. Suggestion: it’s best to perform manual calibration once a week or when NH300 measured data is not accurate.
Since part of the light will pass through the light-transmitting materials, the colorimeter is not suitable for color measurement of such kinds of materials; however, when place a pure color material with uniform texture under the light-transmitting material, we can measure the color difference between the standard and the sample.